Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P

CALL
Update Terakhir
21 Sep 2021
Negara Asal
United States
Pembelian Min
1 Unit

Spesifikasi Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P

Oscilloscopes-Oscilloscope HANTEK DSO5102P


1.Feature

100MHz bandwidths

1GSa/s Real Time sample rate

Large (7.0-inch) color display,WVGA(800x480)

Record length up to 40K

Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.

USB host and device connectivity, standard

Multiple automatic measurements

Four math functions, including FFTs standard

Provides software for PC real-time analysis

VGA Optional


2.Specifications

Model : DSO5102P

Acquisition

Sample Rate : Real-Time Sample: 1GS/s

Acquisition Modes     

Normal : Normal data only

Peak Detect : High-frequency and randon glith capture

Average : Wavefom Average, selectable 4,8,16,32,64,128

Inputs

Inputs Coupling : AC, DC, GND

Inputs Impendance : 1MΩ±2% ‖20pF±3pF

Probe Attenuation : 1X,10X

Supported Probe Attenuation Factor : 1X,10X,100X,1000X

Maximum Input Voltage :

CAT I and CAT II: 300VRMS (10×), Installation Category;

CAT III: 150VRMS (1×);

Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Horizontal System :

Sample Rate Range : 500MS/s--1GS/s

Waveform Interpolation :(sin x)/x

Record Length : 40K

SEC/DIV Range : 4ns/div to 40s/div

Sample Rate and Delay Time Accuracy : ±50ppm(at over any ≥1ms time interval)

Position Range :

20ns/div to 80us/div; (-8div x s/div) to 40ms;

200us/div to 40s/div; (-8div x s/div) to 400s

Delta Time Measurement Accuracy (Full Bandwidth) :

Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);

>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);

Sample interval = s/div ÷ 200

Vertical System

Vertical Resolution : 8-bit resolution, all channel sampled simultaneously

Position Range : 2mV/div to 10V/div

Bandwidth : 100MHz

Rise Time at BNC(typical) : 3.5ns

Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled : 2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V

500mV/div to 2V/div, ±40V; 5V/div, ±50V

Math : +, -, *, /, FFT

FFT : Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;

1024 sample point

Bandwidth Limit : 20MHz

Low Frequency Response(-3db) : ≤10Hz at BNC

DC Gain Accuracy :

±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;

±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

DC Measurement Accuracy,

Average Acquisition Mode :

When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;

When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

Volts Measurement Repeatability,

Average Acquisition Mode : Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

Trigger System

Trigger Types : Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source : CH1, CH2, EXT, EXT/5, AC Line

Trigger Modes : Auto, Normal, Single

Coupling Type : DC, AC, Noise Reject, HF Reject, LF Reject

Trigger Sensitivity(Edge Trigger Type) :

DC(CH1,CH2):

1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;

DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;

DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       

AC: Attenuates signals below 10Hz;

HF Reject: Attenuates signals above 80kHz

LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

Trigger Level Range :

CH1/CH2: ±8 divisions from center of screen;

EXT: ±1.2V;

EXT/5:±6V

Trigger Level Accuracy(typical)Accuracy is for signals having rise and fall times ≥20ns :    

CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;

EXT: ± (6% of setting + 40mV);

EXT/5: ± (6% of setting + 200mV);

Set Level to 50%(typical) : Operates with input signals ≥50Hz

Video Trigger     

Video Trigger Type : CH1, CH2: Peak-to-peak amplitude of 2 divisions;

EXT: 400mV;

EXT/5: 2V

Signal Formats and Field Rates, Video Trigger Type : Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range : 100ns~10s

Pulse Width Trigger     

Pulse Width Trigger Mode : Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

Pulse Width Trigger Point :

Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.

Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.

Less than: The trigger point is the trailing edge.

Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range : 20ns ~ 10s

Slope Trigger     

Slope Trigger Mode : Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

Slope Trigger Point :

Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.

Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.

Less than: The oscilloscope triggers when the waveform slope is less than the set slope.

Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range : 20ns ~ 10s

Overtime Trigger     

Over Time Mode : Rising edge or Falling edge

Time Range : 20ns ~ 10s

Alternative Trigger :     

Trigger on CH1     :

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2 :      

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter

Readout Resolution : 6 digits

Accuracy(typical): ±30ppm (including all frequency reference errors and ±1 count errors)

Frequency Range : AC coupled, from 4Hz minimum to rated bandwidth


 